Your browser is out of date.

You are currently using Internet Explorer 7/8/9, which is not supported by our site. For the best experience, please use one of the latest browsers.

Products From 1- 240 Ton Chillers TC 60 Ton Water Cooled Chiller - Single Circuit

60 Ton Water Cooled Central Chiller - Single Circuit

Thermal Care is at the leading edge of process cooling technology. TC Series centrifugal compressor industrial central chillers use revolutionary, frictionless, magnetic bearing Turbocor compressors to deliver optimum chiller performance and part load efficiencies.This translates into the quietest, most reliable, and most energy efficient chillers ever built. Models are available with either single or completely independent dual refrigeration circuits. 

Request a Quote
  • Model - TCW300C - Single Circuit
  • Cooling Capacity - 60 ton (211 kW)
  • Set Point Range - 40 to 75°F  (4 to 24°C)
  • Compressor Qty - 1
  • MCA @ 460/3/60 - 104 amps
  • MOP @ 460/3/60 - 175 amps
  • Shipping Weight - 1,800 lbs (816 kg)
  • Operating Weight - 2,000 lbs (907 kg)
  • Dimensions - 118" l x 29" w x 77" h 

60 Ton Water Cooled Chiller - Single Circuit Features

  • Water cooled 60 ton central chiller - single circuit
  • Advanced PLC System maintains stable and reliable operation of the chiller
  • Stainless steel brazed plate evaporators for efficiency and corrosion resistance
  • Energy-effficient, variable speed drive, Turbocor centrifugal compressor reduces operating costs vs conventional fixed-speed compressor technologies
  • C-UL 508A listed and labeled industrial control panel
  • Rotary circuit breakers for each compressor
  • Single point connection for electrical hookup at control cabinet
  • Only one major moving part - the compressor impeller which is used to compress gas and provides the highest full load efficiency. In addition, the Turbocor centrifugal compressor design operates at compression ratios as low as 1.2 (discharge pressure/suction pressure) compared to 1.8 or higher for other types of compressors. Lower compression ratios means less energy use.
  • EPA approved low GWP R-513A refrigerant or energy efficient R-134a refrigerant

Oil Free Operation

  • Eliminates oil management system and all related maintenance costs
  • No potential oil contamination of refrigerant
  • No compressor failure due to oil contamination
  • Lower energy required can save up to 40% in annual operating costs when compared to screw-type compressor

Magnetic “Friction-Free” Bearings

  • Equipment life is extended since there is no contact with surfaces as the shaft rotates
  • Compressor senses a power failure as a normal shutdown. Internal capacitors and rotational energy allow the motor to become a generator and provide a fail-safe shutdown.
  • Compressor shaft rests on a graphite-lined touchdown bearing when not in operation

Integrated Variable Speed Drive Motor Control

  • Enhances temperature control capability for partial load performance.
  • Soft-start control reduces peak energy demand and extends motor life by lowering initial current inrush at start-up
  • Lowest noise level; whisper quiet sound levels with 74 dBA (per compressor) and virtually no structure-born vibration

Integrated PLC Control

  • Adaptive control maximize operational performance
  • Provides extensive sensing capabilities and monitors compressor bearing and shaft positions six million times per minute
  • Communications package allows for remote diagnostics of the chiller
  • Built-in 24 VDC control circuitry